Additional Medical Imaging Features

The LEADTOOLS Medical Imaging and LEADTOOLS Medical Imaging Suite provide support for some Image Display and Image Processing features that are not supported in the LEADTOOLS Raster Imaging Pro product. This additional support includes:

·   12 and 16 bit grayscale image features, chosen and optimized to meet the specific demands of the medical imaging market.

·   8-16 bit grayscale lossy and lossless JPEG compression,

·   TWAIN scanning (16-bit grayscale and up to 48-bit color)

·   Importing to/exporting from 10,12 and 16 bit grayscale TIFF files and 48 and 64-bit color TIFF files.

·   Importing to/exporting from JFIF (JPEG) and JTIF (TIFF with JPEG) files compressed using 12-bit grayscale lossy or 16-bit lossless compression.

·   On-the-fly re-mapping of 10 –16 bit grayscale images to Windows display devices, using an LUT with pseudo color support.

·   Painting 10 - 16-bit images using Bilinear or Bi-cubic resizing on-the-fly.

·   12 and 16 bit grayscale image processing and display with LUT and window leveling.

·   16-bit Grayscale histograms

·   Auto detection of the minimum and maximum intensity, and low and high bits used in the image data.

·   Conversion of 12 to 16- bit grayscale images to 8-bit or 24 bit.

·   Creating or loading 12 and 16- bit grayscale and 48 and 64 bit color images from raw data from disk, memory, or file offset.

·   Converting signed images to unsigned images.

·   Converting unsigned images to signed images.

·   16-bit image data in Intel or Motorola formats.

·   Image Overlays.