LEADTOOLS Medical (Leadtools.Dicom assembly) Send comments on this topic. | Back to Introduction - All Topics | Help Version 17.0.3.29
TestConformance Method
See Also 
Leadtools.Dicom Namespace > DicomDataSet Class : TestConformance Method



callback
DicomTestConformanceCallback which will be called to process each DicomElement in the DicomDataSet. This parameter cannot be null.
callback
DicomTestConformanceCallback which will be called to process each DicomElement in the DicomDataSet. This parameter cannot be null.
Verifies the conformance of the Data Set. Supported in Silverlight, Windows Phone 7.

Syntax

Visual Basic (Declaration) 
Public Function TestConformance( _
   ByVal callback As DicomTestConformanceCallback _
) As Boolean
Visual Basic (Usage)Copy Code
Dim instance As DicomDataSet
Dim callback As DicomTestConformanceCallback
Dim value As Boolean
 
value = instance.TestConformance(callback)
C# 
public bool TestConformance( 
   DicomTestConformanceCallback callback
)
C++/CLI 
public:
bool TestConformance( 
   DicomTestConformanceCallback^ callback
) 

Parameters

callback
DicomTestConformanceCallback which will be called to process each DicomElement in the DicomDataSet. This parameter cannot be null.

Example

Visual BasicCopy Code
Public Function DicomTestConformanceCallback(ByVal element As DicomElement, ByVal flags As DicomTestConformanceFlags) As Boolean
   Dim s As String = String.Format("Element: {0}", element.Tag.ToString())
   If flags = DicomTestConformanceFlags.None Then
      Console.WriteLine(s & " no error.")
   Else
      Console.WriteLine(s & " error: " & flags.ToString())
   End If
   Return True
End Function

Public Sub TestConformanceSample()
   Dim dicomFileName As String = LeadtoolsExamples.Common.ImagesPath.Path + "IMAGE3.dcm"
   'Make sure to initialize the DICOM engine, this needs to be done only once 
   'In the whole application
   DicomEngine.Startup()
   Dim ds As DicomDataSet = New DicomDataSet()
   Try
      'Load DICOM File
      ds.Load(dicomFileName, DicomDataSetLoadFlags.None)

      'Test it
      ds.TestConformance(AddressOf DicomTestConformanceCallback)
   Finally
      CType(ds, IDisposable).Dispose()
   End Try
   DicomEngine.Shutdown()
End Sub
C#Copy Code
public bool DicomTestConformanceCallback(DicomElement element, DicomTestConformanceFlags flags)
{
   string s = string.Format("Element: {0}", element.Tag.ToString());
   if (flags == DicomTestConformanceFlags.None)
      Console.WriteLine(s + " no error.");
   else
      Console.WriteLine(s + " error: " + flags.ToString());
   return true;
}

public void TestConformanceSample()
{
   string dicomFileName = LeadtoolsExamples.Common.ImagesPath.Path + "IMAGE3.dcm";
   //Make sure to initialize the DICOM engine, this needs to be done only once 
   //In the whole application
   DicomEngine.Startup();
   using (DicomDataSet ds = new DicomDataSet())
   {
      //Load DICOM File
      ds.Load(dicomFileName, DicomDataSetLoadFlags.None);

      //Test it
      ds.TestConformance(DicomTestConformanceCallback);
   }
   DicomEngine.Shutdown();
}
SilverlightCSharpCopy Code
public bool DicomTestConformanceCallback(DicomElement element, DicomTestConformanceFlags flags)
{
   string s = string.Format("Element: {0}", element.Tag.ToString());
   if (flags == DicomTestConformanceFlags.None)
      Console.WriteLine(s + " no error.");
   else
      Console.WriteLine(s + " error: " + flags.ToString());
   return true;
}
public void TestConformanceSample(Stream dicomStream)
{
   //Make sure to initialize the DICOM engine, this needs to be done only once 
   //In the whole application
   DicomEngine.Startup();
   using (DicomDataSet ds = new DicomDataSet())
   {
      //Load DICOM File
      ds.Load(dicomStream, DicomDataSetLoadFlags.None);

      //Test it
      ds.TestConformance(DicomTestConformanceCallback);
   }
   DicomEngine.Shutdown();
}
SilverlightVBCopy Code
Public Function DicomTestConformanceCallback(ByVal element As DicomElement, ByVal flags As DicomTestConformanceFlags) As Boolean
   Dim s As String = String.Format("Element: {0}", element.Tag.ToString())
   If flags = DicomTestConformanceFlags.None Then
      Console.WriteLine(s & " no error.")
   Else
      Console.WriteLine(s & " error: " & flags.ToString())
   End If
   Return True
End Function
Public Sub TestConformanceSample(ByVal dicomStream As Stream)
   'Make sure to initialize the DICOM engine, this needs to be done only once 
   'In the whole application
   DicomEngine.Startup()
   Using ds As DicomDataSet = New DicomDataSet()
      'Load DICOM File
      ds.Load(dicomStream, DicomDataSetLoadFlags.None)

      'Test it
      ds.TestConformance(AddressOf DicomTestConformanceCallback)
   End Using
   DicomEngine.Shutdown()
End Sub

Remarks

This method will call callback to verify each DicomElement in the DicomDataSet.
The purpose of callback is just to verify that the data provided in the DicomDataSet conforms to the standard.

Requirements

Target Platforms: Silverlight 3.0, Windows XP, Windows Server 2003 family, Windows Server 2008 family, Windows Vista, Windows 7, MAC OS/X (Intel Only)

See Also